Edge-Core ECS3510-28T Management Manual page 1111

Edge-core 28/52-port fast ethernet layer 2 switch
Table of Contents

Advertisement

An ring node with a local manual switch command that receives an
c.
R-APS message or a local request of higher priority than R-APS (MS)
clear its manual switch request. The ring node then processes the
new higher priority request.
Recovery for manual switching under revertive and non-revertive mode
is described under the Command Usage section for the
command.
E
XAMPLE
Console#erps manual-switch domain r&d west
Console#
This command displays status information for all configured rings, or for a
show erps
specified ring
S
YNTAX
show erps [domain ring-name] [statistics]
domain - Keyword to display ERPS ring configuration settings.
ring-name - Name of a specific ERPS ring. (Range: 1-32 characters)
statistics - Keyword to display ERPS ring statistics.
C
OMMAND
Privileged Exec
E
XAMPLE
This example displays a summary of all the ERPS rings configured on the
switch.
Console#show erps
ERPS Status
Number of ERPS Domains
Domain
------------ --- ------- --- --- --------- ---------- ------------ ---------
r&d
Console#
M
ODE
: Enabled
: 1
ID
Enabled Ver MEL Ctrl VLAN State
1 Yes
2
1
W/E
Interface Port State Local SF Local FS Local MS MEP
---- --------- ---------- -------- -------- -------- ---- ---
West Eth 1/ 1
Blocking
East Eth 1/ 3
Forwarding No
– 1111 –
| ERPS Commands
C
34
HAPTER
non-revertive
Type
1 Idle
RPL Owner
No
No
No
No
No
Revertive
Yes
RPL
Yes
No

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecs3510-52t

Table of Contents