• Input Noise Filter: The Input Noise Filter eliminates DMX/ArtNET input oscillation, which can occur on
some DMX control boards. This can cause fine resolution controls (e.g. Lens, Brightness) to continually
change. A filter setting of 0 will turn off the filter; a setting of 1 will filter +/- 1 step changes, etc. Using this
filter will decrease the fine control precision of some slider controls. By default this filter is set to 0 (Off). It
is not recommended to use this feature unless you are experiencing problems with your DMX input.
• Host Name: This will be used to respond to ArtNET polling queries. 'Christie' will be the short name,
'Christie_HostName' will be our long name. By default the host name is composed from the projector name
and serial number. (Default = '<unit name>_<serial no>').
NOTE: The Host name is also defined at Configuration > Communications > Ethernet Settings > Host
Name.

3.9.11SNMP - Submenu

The J Series SNMP (Simple Network Management
Protocol) interface provides network administrators with a
common way to manage their network devices from a
single remote location. SNMP allows an administrator to
query a number of devices to see their current status/
configuration. It also allows operators to change
configuration values and configure trap notifications to be
sent when certain events occur.
The SNMP menu can be accessed from:
Configuration > Communications > SNMP
Controls
Operators are able request the current state of the following controls:
• Power
• Main Input
• Channel
• Lamp Life
• Shutter
• Host Name
• IP Address
Items
Operators are able to request the following status items directly (for quick reference):
• Main software version
• Global alarm status
• Lamp 1 life (just "Lamp Life" if there is no second lamp)
• Lamp 2 life (if applicable)
• Lamp 1 status (just "Lamp Life" if there is no second lamp)
• Lamp 2 status (if applicable)