CHANNEL
GROUP
12
Input
13
Image
14
Image
15
Macro
J Series 2.0, 2.4 and 3.0 kW User Manual
020-100707-03 Rev. 1 (02-2014)
NAME
DESCRIPTION
Input
Projector Channel Selection
1 to 20 Projector Channel 1 to 20
—
86 LOAD
—
Input Selection
111 to 116 Slot 1, Input 1 to 6
121 to 126 Slot 2, Input 1 to 6
131 to 136 Slot 3, Input 1 to 6
141 to 146 Slot 4, Input 1 to 6
—
171 EXECUTE
Size
0 to 255 Scaled as % of total control
range, which is 200 to 4000
Vertical Stretch
0 to 255 Scaled as % of total control
range, which is 200 to 3000
Function
Projector Orientation
0-9 Front Projection
10-19 Rear Projection
20-29 Front Projection Inverted
30-39 Rear Projection Inverted
—
On Screen Display
40-59 OSD On
50-59 OSD Off
60-69 Lens Calibrate
—
86 LOAD
—
Test Pattern
100-104 Off
105-109 Grid
110-114 Grey Scale 16
115-119 White
120-124 Flat Grey
125-129 Black
130-134 Checker
135-139 13 Point
140-144 Color Bars
145-149 Aspect Ratio
150-154 Edge Blend
155-159 Boresight
—
171 EXECUTE
—
Image Freeze
200-209 Freeze image
210-219 Unfreeze image
Appendix B: DMX / ArtNet
DEFAULT
NOTES
VALUE
255
67
91
255
Lens Calibrate is locked
by channel
"Lens shift enable".
B-9