7.5.7 GPIO

Number of I/O Lines
Connector
Output sink current (logic low)
Power output

7.5.8 DMX512 Interface

Connectors
DXM Chain Termination

7.5.9 Built-In Keypad and Display

Key type
Display type
7.5.10Convenience Light
Illumination for input panel
7.6

Power Requirements

PARAMETER
Rated Voltage
Rated Current
Line Frequency
AC Input Coupler
Line Cord
Inrush Current
Maximum Power Consumption
J Series 2.0, 2.4 and 3.0 kW User Manual
020-100707-03 Rev. 1 (02-2014)
High leakage current. Earth connection essential before connecting supply.
POWER
3000W
2400W
1900W
3000W
2400W
1900W
All
3000W
1900W
2400W
3000W
2400W
1900W
All
3000W
2400W
7
Male 9-pin Dsub
100 mA @ 1V typical
12 V ±5% @ 400mA maximum
Two 5-pin XLR one male (input) and one female (output)
Configurable via software
Soft-touch keys
Graphics LCD backlight
Provided by a dual-strip dedicated switch on the built-in
keypad.
REQUIREMENT
200 VAC - 240 VAC
200 VAC - 240 VAC
200 VAC - 240 VAC
20 A
16 A
14 A
50/60 Hz
32 A, 250 VAC, IEC 309
20 A, 250 VAC, IEC 320-C20
20 A, 250 VAC, IEC 320-C20
10AWG type SJT with plug, NEMA L6-30P, 30A
12AWG type SJT with plug, NEMA 6-20P, 20A
12AWG type SJT with plug, NEMA 6-20P, 20A
60 A max
4000W
3200W
Section 7: Specifications
7-9