5. Make sure the lamp insertion/removal handle hook is located behind the lamp module and pull lamp module
off of electrical terminal by pulling on the insertion/removal handle. Carefully pull on the lamp module
handle to remove the lamp. If the lamp is to be discarded, follow safe disposal/recycling procedures.
6. In the lamp menu, select CHANGE LAMP. This will prompt for the old lamp serial number (if it was not
previously entered). Enter the new lamp serial number.
NOTE: This action is not mandatory, it is recommended for accurate lamp statistics to be archived.
7. Align the base plate of the new lamp module under both side alignment
the projector in the same orientation you removed the old lamp module until the resistance increases.
NOTE: A slightly harder push may be required to ensure it is fully seated. Lamp alignment marks are
provided to indicate the fully seated position.
8. Secure the insertion/removal lever by threading the know into the threaded block by hand or using a
Phillips screwdriver.
9. Using a Phillips screwdriver, secure the lamp door.
J Series 2.0, 2.4 and 3.0 kW User Manual
020-100707-03 Rev. 1 (02-2014)
Section 5: Maintenance
guides,
then slide the module into
5-3