Nmea 0183 Output Sentences; Alarms - Standard Horizon CPN1010i Owner's Manual

Multimedia gps chart plotters
Hide thumbs Also See for CPN1010i:
Table of Contents

Advertisement

NMEA 0183 output sentences

The ports may be setup to output NMEA sentences. The table below shows the default
setting each port:
Sentence
GLL
VTG
BWC
WCV
APA
APB
HDG
BOD
XTE
RMA
RMB
RMC
GGA
HSC
DBT
DPT
MTW
VHW
GSA
GSV

ALARMS

This menu is used to select and setup audible and visual alarms. See the following table:
Arrival Alarm:
XTE Alarm:
Depth Alarm:
Anchor Alarm:
Audible Alarm:
External Alarm:
Grounding Alarm:
Grounding Alarm Range: Sets the length of the sector to be detected among 0.25 Nm, 0.5 Nm and 1.0 Nm.
Grounding Alarm Report: Displays the report of the dangerous objects currently detected. When any of the searched
Page 104
Port1
Port2
On
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
On
Off
Off
Off
Off
On
On
On
On
Off
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
Alerts when the vessel is approaching a single destination point or when arriving at a leg
in a Route. Available selections: 0.00 to 9.99NM.
Alerts when the vessel is deviating from a defined course. Available selections: 0.00 to
9.99NM.
Alerts when the received depth value from the optional FF525 50/200kHz BLACK BOX
FISH FINDER or Depth Finder inputting NMEA data into the CPN Series Chart Plotter is
lower than the selected value. Available selections: 0000 to 3000FT.
Alerts when the ships moves off a selected locations by a selected distance. Available
selections: 0.00 to 9.99NM.
Enables or disables the alarm beep.
Enables or disables the External Alarm. When any alarm condition occurs the red wire is
switched from High Impedance to Ground. When purchasing the optional buzzer, choose
a 12VDC type with a Max current 400mA or less.
Looks ahead of the vessels heading to see if a potential danger exists. When the Grounding
Alarm is enabled the CPN Series Chart Plotter will draw a triangle in front of the vessel on
the Chart Page showing the area that is being searched as shown below. The depth and
range (distance) of the area the CPN Series Chart Plotter looks ahead for a shallow area can
be set using this function.
objects is found in the scanned area, a tick marker is printed on the relative box to identify
which dangerous objects have been currently detected. Once the alarm condition is no
longer present, the relative tick marker is removed.
Port3
Port4
On
On
Off
Off
Off
Off
Off
Off
On
Off
On
Off
Off
Off
On
Off
On
On
Off
Off
Off
Off
On
On
On
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Owner's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpn700i

Table of Contents