19-Inch, 2-Post Hardmount Rack Screw Kit Contents
TABLE:
No.
Description
10
M5 x 7 SEM screws
6
M3 x 8 SEM screws
10
M5 x 12.7 mm screws
10
M6 x 13 mm screws
9
M6 square clip nuts
12
10-32 x 0.5 in. combo head screws
12
12-24 x 0.5 in. combo head screws
Related Information
"Install the Server (19-Inch, 2-Post Hardmount Rackmount Kit)" on page 51
■
▼ Install the Server (19-Inch, 2-Post Hardmount
Rackmount Kit)
Note – The 19-inch, 2-post rackmount kit supports rack web thicknesses (the width
of the rack post) of 76.20 mm (3 in.), 101.6 mm (4 in.), and 127 mm (5 in.).
1. Read the Cautions for racks.
See
"Rack Cautions" on page
2. Using four of the M5 x 7 SEM screws for each side bracket, secure the side
brackets to the sides of the server.
Where Used
8 for side brackets, 2 extra
4 for rear plates, 2 extra
10 for rack, if appropriate
10 for rack, if appropriate
9 for rack, if appropriate
12 for rack, if appropriate
12 for rack, if appropriate
20.
Installing the Server
51