Operation panel FR-DU07
4.3.5

Monitoring of output current and output voltage

Monitor display of output frequency, output current and output voltage can be changed by push-
ing the SET key during monitoring mode.
Press the MODE key during operation to choose
the output frequency monitor.
(Hz indication is lit.)
Independent of whether the inverter is running
in any operation mode or at a stop, the output
current monitor appears by pressing the SET key.
(A indication is lit.)
Press the SET key to show the output voltage
monitor.
(V indication is lit.)
Fig. 4-7: Monitoring of output current and output voltage
4.3.6

First priority monitor

Hold down the SET key for 1s to set monitor description to be appeared first in the monitor mode.
(To return to the output frequency monitor, hold down the SET key for 1s after displaying the out-
put frequency monitor.)
4.3.7

Digital dial push

During PU operation mode and External/PU combined operation mode 1 (Pr. 79 = "3"), push the
setting dial to display the set frequency currently set.
4 - 12
Operation
Fig. 4-8:
Display the set frequency currently set
Operation
Display
I001066E
I001067E