4.3

Operation panel FR-DU07

4.3.1

Parts of the operation panel

Fig. 4-3: Parts of the operation panel FR-DU07
FR-F700 EC
Operation panel FR-DU07
LED-Display
4-digit 7-segment display for opera-
tional values, parameter numbers, etc.
(For selecting a monitoring item set
Pr. 52 and Pr. 774 to Pr. 776.)
Unit indication
LED to indicate the current unit
Frequency (flickers when the set
frequency monitor is displayed)
Current
Voltage
Operation mode indication
LED to indicate the operation mode
PU operation mode (PU)
External operation mode (EXT)
At power-ON in the initial setting
(EXT)
Network operation mode (NET)
EXT/PU combined operation mode
1 or 2 (PU and EXT)
PLC function indication
LED to indicate that the PLC function
is active
Monitor indication
LED to indicate monitoring mode.
Rotation direction indication
LED to indicate the operation mode
Forward rotation (FWD)
Reverse rotation (REV)
Forward/reverse operation (ON)
Flickering when the frequency
command is not given even if the
forward/reverse command is given.
Flickers when the frequency
command is lower than the starting
frequency
Flickers when the MRS signal is
being input
I001055E