Mitsubishi Electric FR-F740 EC Instruction Manual page 157

Fr-f700 series
Table of Contents

Advertisement

Parameter
Parameter
Func-
Name
tion
CA terminal function
54
selection
Frequency monitoring
55
reference
Current monitoring
56
reference
AM terminal function
158
selection
AM output filter
867
Current output filter
869
57
Restart coasting time
58
Restart cushion time
Automatic restart after
instantaneous power
162
failure selection
First cushion time for
163
restart
First cushion voltage
164
for restart
Stall prevention opera-
165
tion level for restart
Rotation direction
detection selection at
299
restarting
Acceleration time at a
611
restart
Tab. 6-1:
Parameter overview (7)
FR-F700 EC
Incre-
Initial
Setting
ments
Value
Range
1–3/5/6/
8–14/17/21/
1
1
24/50/52/
53/67/70/85
0.01Hz
50Hz
0–400Hz
Rated
0.01/
0–500/
inverter
0.1A *
0–3600A *
current
1–3/5/6/
8–14/17/21/
1
1
24/50/52/
53/67/70/86
0.01s
0.01s
0–5s
0.01s
0.02s
0–5s
0
0.1s
9999
0.1–5s/
0.1–30s *
9999
0.1s
1s
0–60s
0
1
1
0
10
11
0.1s
0s
0–20s
0.1%
0%
0–100%
0.1%
110%
0–120%
0
1
1
9999
9999
0–3600s
0.1s
5/15s *
9999
Description
Select the monitor output to
terminal CA.
The setting value of "9" is available
only for the 01800 or more.
Set the full-scale value to output
the output frequency monitor
value to terminal CA and AM.
Set the full-scale value to output
the output current monitor value
to terminal CA and AM.
* The setting depends on the
inverter capacity:
(01160 or less/01800 or more)
Select the monitor output to
terminal AM.
The setting value of "9" is available
only for the 01800 or more.
Set the output filter of terminal AM.
Adjust response level of current
output.
The coasting time is as follows:
00038 or less:...................... 0.5s,
00052–00170: ........................ 1s,
00250–01160: ..................... 3.0s,
01800 or more:..................... 5.0s
Set the waiting time for inverter-
triggered restart after an instanta-
neous power failure.
* The setting depends on the
inverter capacity:
(01160 or less/01800 or more)
No restart
Set a voltage starting time at
restart.
With frequency search
Without frequency search
(Reduced voltage system)
Frequency search at every start
Reduced voltage system at every
start
Set a voltage starting time at
restart.
Consider according to the magni-
tude of load (inertia moment/
torque).
Consider the rated inverter current
as 100% and set the stall preven-
tion operation level during restart
operation.
Without rotation direction detection
With rotation direction detection
When Pr. 78 = "0", the rotation
direction is detected.
When Pr. 78 = "1", "2", the rotation
direction is not detected.
Set the accel-
eration time to
reach the set
* The setting
frequency at a
depends on the
restart.
inverter capac-
Acceleration
ity:
time for
(01160 or less/
restart is the
01800 or more)
normal accel-
eration time
(e.g. Pr. 7).
Parameter overview
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
6-146
6-153
6 - 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-f746 ec

Table of Contents