Parameter overview
Parameter
Func-
Name
tion
Second pre-charge
765
fault selection
Second pre-charge
766
ending level
Second pre-charge
767
ending time
Second pre-charge
768
upper detection level
Second pre-charge
769
time limit
PU/DU monitor
774
selection 1
PU/DU monitor
775
selection 2
PU/DU monitor
776
selection 3
777
Refer to Pr. 73
778
—
779
Refer to Pr. 502
Pulse increment set-
—
799
ting for output power
826
—
–
Refer to Pr. 414 and Pr. 415
865
867
—
Refer to Pr. 54 to Pr. 56
869
—
870
Refer to Pr. 41–Pr. 43
—
872
Refer to Pr. 251
Tab. 6-1:
Parameter overview (34)
6 - 34
Incre-
Initial
Setting
ments
Value
Range
0
1
0%
1
0–100%
0.1%
9999
9999
0–3600s
0.1s
9999
9999
0–100%
0.1%
9999
9999
0–3600s
0.1s
9999
9999
1– 3/5/6/
8 –14/17/
20/23– 25/
1
9999
40–42/
50 –57/64/
67/81–86/
100/9999
0.1/1/10/
0.1
1kWh
100/
1000kWh
Description
When the pre-charged amount
exceeds Pr. 768 or the pre-
charged time exceeds Pr. 769
while the RT signal is ON, the out-
put is immediately shutoff, and the
fault (E.PCH) is output.
When the pre-charged amount
exceeds Pr. 768 or the pre-
charged time exceeds Pr. 769
while the RT signal is ON, the
motor decelerates to stop, and the
fault (E.PCH) is output.
Set the measurement level to end
the pre-charge operation, which is
performed while the RT signal is
ON.
Without second pre-charge ending
level
Set the time to end the pre-charge
operation, which is performed
while the RT signal is ON.
Without second pre-charge ending
time
Set the upper limit for the pre-
charged amount, which is charged
while the RT signal is ON. If the
pre-charged amount exceeds the
set level, the fault (E.PCH) is out-
put.
Without second pre-charge ending
level
Set the time limit for the pre-
charge operation, which is per-
formed while the RT signal is ON.
If the pre-charged time exceeds
the set level, the fault (E.PCH) is
output.
Without second pre-charge time
limit
Select the monitored item to be
displayed on the first monitor (first
row in the 3-line monitor).
Select the monitored item to be
displayed on the second monitor
(second row in the 3-line moni-
tor).
Select the monitored item to be
displayed on the third monitor
(third row in the 3-line monitor).
Pulse train output of output power
(Y79) is output in pulses at every
output power (kWh) that is
specified.
Parameter
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
✔
✔
✔
✔
✔
✔
6-350
6-358
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
6-358
✔
✔
✔
6-416
✔
✔
✔
✔
✔
✔