Monitoring Of Output Current And Output Voltage; First Priority Monitor; Digital Dial Push - Mitsubishi Electric FR-E700 Series Instruction Manual

Hide thumbs Also See for FR-E700 Series:
Table of Contents

Advertisement

Operation panel
4.3.5

Monitoring of output current and output voltage

Monitor display of output frequency, output current and output voltage can be changed by pushing
the SET key during monitoring mode.
Fig. 4-10: Monitoring of output current and output voltage
4.3.6

First priority monitor

Hold down the SET key for 1s to set monitor description to be appeared first in the monitor mode. (To
return to the output frequency monitor, hold down the SET key for 1s after displaying the output fre-
quency monitor.)
4.3.7

Digital dial push

Appears when PU operation mode or external/PU combined operation mode 1 is selected (Pr. 79 =
"3").
Push the digital dial to display the set frequency currently set.
4 - 14
Operation
Press the MODE key during operation to choose
the output frequency monitor.
(Hz indication is lit.)
Independently of whether the inverter is running
in any operation mode or at a stop, the output
current monitor appears by pressing the SET key.
(A indication is lit.)
Press the SET key to show the output voltage
monitor.
(Hz and A indication are turned off.)
Fig. 4-11:
Display the set frequency currently set
Operation
Display
I001740E
I001067E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents