Frequency setting by external terminals
JOG operation from PU
Set the PU (FR-DU07/FR-PU04/FR-PU07) to the jog operation mode. Operation is performed
only while the start button is pressed.
Confirmation of the RUN indication and operation
mode indication.
The monitor mode must have been selected.
The inverter must be at a stop.
Press the PU/EXT key to choose the
PU JOG operation mode.
Press the FWD or REV key.
The motor rotates while the key is pressed.
It rotates at 5Hz (initial value of Pr. 15).
Release the FWD or REV key to stop the motor.
When changing the frequency of PU JOG operation:
Press the MODE key to choose the parameter
setting mode.
Turn the digital dial until Pr. 15 "JOG frequency"
appears.
Press the SET key to show the currently set value
(5Hz).
Turn the digital dial to set the value to "10.00"
(10.00Hz).
Press the SET key to set.
Perform the operations in steps
The motor rotates at 10Hz.
Fig. 6-24:
6 - 68
Inverter
Power
supply
Operation
JOG operation performed from PU
Fig. 6-23:
Connection example for jog operation
performed from PU
Motor
Hold down
Release
to
Parameter
I001130E
Display
Stop
The parameter number
read previously
appears.
Flicker ... Parameter setting complete!
I001131E