Mitsubishi Electric FR-F740 EC Instruction Manual page 341

Fr-f700 series
Table of Contents

Advertisement

Parameter
Set the voltage/current input switch referring to the table below.
Terminal 2 Input
Specifications
Voltage input
(0 to 10V)
Voltage input
(0 to 5V)
Current input
(0 to 20mA)
Tab. 6-34:
Indicates an initial value.
NOTES
Turn the AU signal on to make terminal 4 valid.
Match the setting of parameter and switch. A different setting may cause a fault, failure or
malfunction.
The terminal 1 (frequency setting auxiliary input) signal is added to the main speed setting
signal of the terminal 2 or 4.
When an override is selected, the terminal 1 or 4 is used for the main speed setting and the
terminal 2 for the override signal (50% to 150% at 0 to 5V or 0 to 10V). (When the main
speed of the terminal 1 or terminal 4 is not input, compensation by the terminal 2 is made
invalid.)
Use Pr. 125 (Pr. 126) "Frequency setting gain" to change the maximum output frequency at
input of the maximum output frequency command voltage (current). At this time, the com-
mand voltage (current) need not be input. Also, the acceleration/deceleration time, which is a
slope up/down to the acceleration/deceleration reference frequency, is not affected by the
change in Pr. 73 setting.
When Pr. 22 "Stall prevention operation level" = 9999, the value of the terminal 1 is as set to
the stall prevention operation level.
When Pr. 561
FR-F700 EC
Pr. 73 setting
0, 2, 4, 10, 12, 14
1 (initial value), 3, 5,
11, 13, 15
6, 7, 16, 17
Setting the voltage/current input switch
"9999", terminal 2 is not available for analog frequency command.
Frequency setting by analog input (terminals 1, 2 and 4)
Terminal 4 Input
Switch 2
Specifications
Voltage input
OFF
(0 to 10V)
Voltage input
OFF
(0 to 5V)
Current input
ON
(0 to 20mA)
Pr. 267 setting
Switch 1
2
OFF
1
OFF
0 (initial value)
ON
6 - 191