Parameter overview
Parameter
Func-
Name
tion
Traverse function
592
selection
Maximum amplitude
593
amount
Amplitude
594
compensation amount
during deceleration
Amplitude
595
compensation amount
during acceleration
Amplitude
596
acceleration time
Amplitude
597
deceleration time
611
Refer to Pr. 57 and Pr. 58
Speed smoothing
653
control
Speed smoothing
654
cutoff frequency
665
Refer to Pr. 882 to Pr. 886
Auto Baudrate/Max
726
Master
727
Max Info Frames
Device instance
728
number (Upper 3 digit)
Device instance
729
number (Lower 4 digit)
Tab. 6-1:
Parameter overview (30)
6 - 30
Incre-
Initial
Setting
ments
Value
Range
0
1
1
0
2
0.1%
10%
0–25%
0.1%
10%
0–50%
0.1%
10%
0–50%
1s
5s
0.1–3600s
1s
5s
0.1–3600s
0.1%
0
0–200%
0.01Hz
20Hz
0–120Hz
1
255
0–255
1
1
1–255
0–419
1
0
(0–418)
0–9999
1
0
(0–4302)
Description
Traverse function invalid
Traverse function is valid only in
the external operation mode
Traverse function is valid inde-
pendent of operation mode
Amplitude amount during traverse
operation
Compensation amount at the time
of amplitude inversion
(acceleration → deceleration)
Compensation amount during
amplitude inversion operation
(deceleration → acceleration)
Acceleration time during traverse
operation
Deceleration time during traverse
operation
The torque fluctuation is reduced
to reduce vibration due to
mechanical resonance.
Set the minimum value for the
torque variation cycle (frequency).
Auto baud rate (bit7)
Setting range:
0: Inactive
1: Active
Max Master (bit0 to bit6) setting
range: 0 to 127
Maximum address for master
node
Set the maximum number of mes-
sages that the inverter can trans-
mit while it owns the token.
Device identifier (Duplicated set-
ting available)
Setting range of the combination
of Pr. 728 and Pr. 729 are "0 to
4194302".
Example:
When Pr.728 = "419", setting range
of Pr. 729 is "0 to 4302".
When Pr.729 = "4303" or more,
setting range of Pr. 728 is "0 to
418".
Parameter
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
6-375