Parameter; Parameter Overview - Mitsubishi Electric FR-F740 EC Instruction Manual

Fr-f700 series
Table of Contents

Advertisement

Parameter

6
Parameter
6.1

Parameter overview

Parameter 160 is factory set to "9999". That means that only the parameters marked with
the following table are accessible. Set parameter 160 to "0" to access other or all parameters.
The half-tone screened parameters allow its setting to be changed during operation even if "0"
(initial value) is set in Pr. 77 "Parameter write selection".
Parameter
Func-
Name
tion
0
Torque boost
Second torque boost
46
1
Maximum frequency
2
Minimum frequency
High speed maximum
18
frequency
3
Base frequency
Base frequency voltage
19
Second V/f (base
47
frequency)
Tab. 6-1:
Parameter overview (1)
FR-F700 EC
Incre-
Initial
Setting
ments
Value
Range
6/4/3/
0.1%
0–30%
2/1.5/1 *
0–30%
0.1%
9999
9999
120/
0.01Hz
0–120Hz
60Hz *
0.01Hz
0Hz
0–120Hz
120/
0.01Hz
120–400Hz
60Hz *
0.01Hz
50Hz
0–400Hz
0–1000V
0.1V
8888
8888
9999
0–400Hz
0.01Hz
9999
9999
Description
Set the output voltage at 0Hz as %
* Initial values differ according to
the inverter capacity:
Initial
Inverter capacity
value
00023
6%
00038–00083
4%
00125/00170
3%
00250–00770
2%
00930/01160
1.5%
01800 or more
1%
Set the torque boost when the RT
signal is on.
Without second torque boost
Set the upper limit of the output
frequency
* The setting depends on the
inverter capacity:
(01160 or less/01800 or more)
Set the lower limit of the output
frequency
Set when performing operation at
120Hz or more
* The setting depends on the
inverter capacity:
(01160 or less/01800 or more)
Set the frequency when the motor
rated torque is generated.
(50Hz/60Hz)
Maximum inverter output voltage
95% of power supply voltage
Same as power supply voltage
Set the base frequency when the
RT signal is on.
Second V/f is invalid.
Parameter overview
in
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
6-39