Parameter
● Parameter
Parame-
ters
0–999
C2 (902)
C3 (902)
125 (903)
C4 (903)
C5 (904)
C6 (904)
126 (905)
C7 (905)
C8 (930)
C9 (930)
C10 (931)
C11 (931)
C42 (934)
C43 (934)
C44 (935)
C45 (935)
Tab. 6-91:
FR-F700 EC
Register Parameter Name
Refer to the parameter list
41000–
(Tab. 6-1) for the parameter
41999
names.
Terminal 2 frequency setting bias
41902
(frequency)
Terminal 2 frequency setting bias
42092
(analog value)
Terminal 2 frequency setting bias
43902
(terminal analog value)
Terminal 2 frequency setting gain
41903
(frequency)
Terminal 2 frequency setting gain
42093
(analog value)
Terminal 2 frequency setting gain
43903
(terminal analog value)
Terminal 4 frequency setting bias
41904
(frequency)
Terminal 4 frequency setting bias
42094
(analog value)
Terminal 4 frequency setting bias
43904
(terminal analog value)
Terminal 4 frequency setting gain
41905
(frequency)
Terminal 4 frequency setting gain
42095
(analog value)
Terminal 4 frequency setting gain
43905
(terminal analog value)
41930
Current output bias signal
42120
Current output bias current
41931
Current output gain signal
42121
Current output gain current
41934
PID display bias coefficient
42124
PID display bias analog value
PID display bias analog value
43934
(terminal analog value)
41935
PID display gain coefficient
42125
PID display gain analog value
PID display gain analog value
43935
(terminal analog value)
Parameter
Communication operation and setting
Read/Write
Remarks
The parameter number +
Read/write
41000 is the register number.
Read/write
The analog value (%) set to
Read/write
C3 (902) is read.
The analog value (%) of the
Read
voltage (current) applied to the
terminal 2 is read.
Read/write
The analog value (%) set to
Read/write
C4 (903) is read.
The analog value (%) of the
Read
voltage (current) applied to the
terminal 2 is read.
Read/write
The analog value (%) set to
Read/write
C6 (904) is read.
The analog value (%) of the
Read
current (voltage) applied to the
terminal 4 is read.
Read/write
The analog value (%) set to
Read/write
C7 (905) is read.
The analog value (%) of the
Read
current (voltage) applied to the
terminal 4 is read.
Read/write
Read/write
Read/write
Read/write
Read/write
The analog value (%) set to
Read/write
C43 (934) is read.
The analog value (%) of the
Read
current (voltage)applied to the
terminal 4 is read.
Read/write
The analog value (%) set to
Read/write
C45 (935) is read.
The analog value (%) of the
Read
current (voltage) applied to the
terminal 4 is read.
6 - 305