EPSON Stylus Photo R1800/R2400
Pass the CR Scale through the slot on the CR Encoder.
CR Encoder
CR Scale
Figure 4-42. Reinstalling the CR Scale (1)
Set the left end of the CR Scale with the chamfered edge
facing upwards.
Chamfered edge
CR Scale
Figure 4-43. Reinstalling the CR Scale (2)
Place the right end of the CR Scale correctly so that it is
not hooked onto the Right CR Shaft Mounting Plate.
CR Scale
Figure 4-44. Reinstalling the CR Scale (3)
Disassembly And Assembly

4.2.6.3 APG Assy

1. Remove the Upper Housing.
2. Disconnect the APG Motor Connector Cable from Connector CN18 (red)
on the Main Board, and Remove the Cable from the ASF Assy.
3. Disconnect the Connector Cables from the two APG Sensor Connectors.
OK
NG
Hooked Portion
Disassembly
See Section 4.2.1.4 on page 76.
APG Sensor Connectors
CN18
Figure 4-45. Disconnecting the Connector Cables
Referring to
Figure
4-45., correctly route the APG Connector
Cable.
Revision B
APG Motor
APG Assy
93