Apg Assy. Removal - Epson Stylus Photo R220 Service Manual

Hide thumbs Also See for Stylus Photo R220:
Table of Contents

Advertisement

EPSON Stylus Photo R220/R230

2.3.9 APG Assy. Removal

External View
C.B.S. 3x6 (6-8kgf.cm)
Figure 2-22. APG Assy. Removal
Parts/Units which should be removed before removing APG Assy.
Paper Support Assy./Housing (left/right)/Housing, Frame/ASF Assy./Main Board
Assy.
DISASSEMBLY / ASSEMBLY
Disassembly Procedure
1.
Left Rear Side
APG Assy.
Disassembly
Remove the screw that secures the APG Assy. to the Frame, Main, and
remove the assy. avoiding contact with the Frame, Main.
When reinstalling the APG Assy.
Make sure that the two tabs and the two dowels are securely
installed to the Frame, Main.
Check if the part indicated in
slits of the Frame, Main.
Insert this into the
slit of the Frame,
Main.
Dowels
Figure 2-23. APG Assy. Installation
Revision A
Figure2-23
is inserted in the
Tabs
APG Assy.
62