4.2.8 Removing the Sensors

4.2.8.1 PE Sensor Holder

1. Remove the ASF Assy.
See Section 4.2.4 on page 83.
2. Remove the PE Sensor Connector Cable from the five Tabs on the
Release Holder Assy and the two Tabs on the Head Cable Cover.
Head Cable Cover
Release Holder Assy.
Figure 4-135. Releasing the Cables
3. Release the Tabs that secure the PE Sensor Holder from the notch on the
Main Frame with a flat-blade screwdriver, and slide upwards and then
remove toward you.
Front
Tab
Figure 4-136. Removing the PE Sensor Holder
Disassembly And Assembly
Tabs
PE Sensor Connector Cable
Tabs
PE Sensor Holder
Align the four Tabs and Guide Pin on the PE Sensor Holder
with the positioning holes on the Main Frame correctly so
that there is no gap between the PE Sensor Holder and the
Main Frame.
Disassembly
Tabs
Figure 4-137. Reinstalling the PE Sensor
Revision B
Guid
Guide pin
124