EPSON Stylus Photo R1800/R2400
4. While pressing the Guide Pin on the PF Encoder Sensor Holder using
tweezers, slide the Holder upwards to release the three Tabs, and remove
the PF Encoder Sensor Holder.
Guide Pin
Figure 4-142. Removing the PF Encoder Sensor Holder
Make sure that the PF Scale is in the slit on the PF Encoder
Sensor.
PF Scale
Figure 4-143. Reinstalling the PF Encoder Sensor Holder
Disassembly And Assembly
Tabs
Slit
PF Encoder Sensor
Disassembly
Revision B
127