EPSON Stylus Photo R1800/R2400
Occurrence
Phenomenon Detail
Timing
At power-on
The power-on sequence is
executed but Fatal error is
displayed.
At power-on, the PF Motor
does not operate at all.
Troubleshooting
Table 3-12. Troubleshooting of Fatal Error
Faulty Part/
Part Name
CR drive
1. Check that the Carriage Shaft is lubricated with grease.
mechanism
Carriage Shaft
PF Motor
1. Check that the Connector Cable of the PF Motor is
connected to the Main Board Connector CN16.
CN16
2. Check the PF Motor connector cable for damages.
3. Check if the PF Motor operates normally.
Overview
Check Point
PF Motor
Revision B
Remedy
1. Wipe the surface of the Carriage Shaft with
a dry, soft cloth, and lubricate the Carriage
Shaft with grease G-71.
Refer to Chapter 6 "Maintenance".
1. Connect the PF Motor connector cable to
the Main Board Connector CN16.
2. Replace the PF Motor with a new one.
3. Replace the PF Motor with a new one.