5. Remove the coil section of Torsion Spring 24.7 from the Tab on the Left
CR Shaft Mounting Plate with tweezers.
Left CR Shaft
Mounting Plate
Torsion Spring 24.7
Figure 4-39. Removing the Torsion Spring 24.7 (1)
6. Remove Torsion Spring 24.7 from the CR Scale by the following
procedure:
6-1.
Stand the coil section.
6-2.
Lower the coil section downwards to remove Foot 1 from the notch
on the Left CR Shaft Mounting Plate.
6-3.
Turn the coil section counterclockwise.
6-4.
Remove Torsion Spring 24.7 from the hole on the CR Scale.
Step 6-3
Figure 4-40. Removing the Torsion Spring 24.7 (2)
Disassembly And Assembly
Tab
Step 6-1
Foot 1
Notch
Step 6-2
7. Turn the CR Scale 90º, and remove it from the Tab on the Left CR Shaft
Mounting Plate.
Figure 4-41. Removing the CR Scale