EPSON Stylus Photo R1800/R2400
5. Remove the coil section of Torsion Spring 24.7 from the Tab on the Left
CR Shaft Mounting Plate with tweezers.
Left CR Shaft
Mounting Plate
Torsion Spring 24.7
Figure 4-39. Removing the Torsion Spring 24.7 (1)
6. Remove Torsion Spring 24.7 from the CR Scale by the following
procedure:
6-1.
Stand the coil section.
6-2.
Lower the coil section downwards to remove Foot 1 from the notch
on the Left CR Shaft Mounting Plate.
6-3.
Turn the coil section counterclockwise.
6-4.
Remove Torsion Spring 24.7 from the hole on the CR Scale.
Step 6-3
Figure 4-40. Removing the Torsion Spring 24.7 (2)
Disassembly And Assembly
Tab
Step 6-1
Foot 1
Notch
Step 6-2
7. Turn the CR Scale 90º, and remove it from the Tab on the Left CR Shaft
Mounting Plate.
Figure 4-41. Removing the CR Scale
Disassembly
Revision B
Tab
92