Disassembling The Printer Mechanism; Apg Assy - Epson Stylus Photo R2000s Series Service Manual

Table of Contents

Advertisement

EPSON Stylus Photo R1900/R2880/R2000/R2000s/SC-P400 Series

4.4 Disassembling the Printer Mechanism

4.4.1 APG Assy

1.
Remove the Upper Housing / Printer Cover. (p.83)
2.
Disconnect the APG Motor connector cable from connector CN18 (red) on the
Main Board, and Remove the cable from the ASF Assy.
3.
Disconnect the cables from the two APG Sensor connectors.
Hook the APG Motor
cable on the two tabs
of the ASF Assy.
Figure 4-40. Disconnecting the Cables
Referring to
Figure
4-40, correctly route the APG connector cable.
Disassembly And Assembly
APG Motor
APG Assy
APG Sensor connectors
CN118
Disassembling the Printer Mechanism
4.
Remove the three C.B.S. M3 x 6 screws that secure the APG Assy, and remove the
APG Assy from the Main Frame.
1
2
Figure 4-41. Removing the APG Assy
When installing the APG Assy, confirm the FLAG Release Assy
is not in the released state (with the Upper Paper Guide up).
Upper Paper Guide
Released
Figure 4-42. Reinstalling the APG Assy
Revision I
2) C.B.S. M3x6
(8±1 kgf.cm)
3
FLAG Release Assy
Not Released
91