8.4.2 Tracks/Protocol

Via parameter
analog Tracks/Protocol of the encoder and evaluation of a reference track.
Key of Tracks/Protocol:
Note:
Tracks/Protocol
0 - off
SinCos
100 - A/B
300 - A/B, C/D
500 - A/B, R
700 - A/B, C/D, R
EnDat 2.1
1101 EnDat 2.1
Hiperface
Hiperface,
3109
9.6 kBit/s
Hiperface,
3119
19.2 kBit/s
Hiperface,
3138
38.4 kBit/s
03/12
1184 , you can specify the type-specific number of
Tracks/Protocol
The identifiers of track A/B and Sin/Cos are typically ambivalent and can
be set to A = Sin and B = Cos.
1184
Evaluation is turned off. Factory setting .
Evaluation of analog Tracks/Protocol A and B.
Evaluation of analog Tracks/Protocol A and B and commuta-
tion Tracks/Protocol C and D.
Evaluation of analog Tracks/Protocol A and B as well as refer-
ence track R. Monitoring and comparison of Tracks/Protocol.
Evaluation of analog Tracks/Protocol A and B and commuta-
tion Tracks/Protocol C/E as well as reference track R. Monitor-
ing and comparison of Tracks/Protocol.
Evaluation of analog Tracks/Protocol A/B and the data and
clock track with the EnDat 2.1 protocol. Monitoring and com-
parison of Tracks/Protocol.
Evaluation of analog Tracks/Protocol A/B and the data tracks
with the Hiperface protocol. Monitoring and comparison of
Tracks/Protocol. The data track is transmitted at 9.6 kBaud.
Like 3109. The data track is transmitted at 19.2 kBaud.
Like 3109. The data track is transmitted at 38.4 kBaud.
EM-ABS-01 for ACU
Function