Tolerance Band And Hysteresis - BONFIGLIOLI Active Cube User Manual

Frequency inverter 230 v/400 v
Hide thumbs Also See for Active Cube:
Table of Contents

Advertisement

8.1.5 Tolerance Band and Hysteresis

The analog input characteristic with change of sign of the reference value can be
adapted by the parameter
to be defined extends the zero crossing of the speed relative to the analog control
signal. The parameter value (percent) is relative to the maximum current or voltage
signal.
No.
560 Tolerance band
pos. max. value
-10V
(-20mA)
Without tolerance band
The default
rameterized tolerance band to the hysteresis.
pos. max. value
pos. min. value
neg. min. value
With tolerance band and minimum value
For example, the output variable coming from positive input signals is kept on the
positive minimum value until the input signal becomes lower than the value for the
tolerance band in the negative direction. Then, the output variable follows the set
characteristic.
03/12
Tolerance band
Parameters
Description
(X2 / Y2)
+10V
(+20mA)
(X1 / Y1)
neg. max. value
418 or
Minimum Frequency
(X2 / Y2)
Tolerance band
(X1 / Y1)
neg. max. value
EM-ABS-01 for ACU
560 of the application. The tolerance band
Settings
Min.
Max.
0,00%
25,00%
pos. max. value
-10V
(-20mA)
Tolerance band
(X1 / Y1)
With tolerance band
518 extends the pa-
Minimum Percentage
Factory set-
ting
2,00%
(X2 / Y2)
+10V
neg. max. value
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Active cube em-abs-01

Table of Contents