Keypad Functions
General
Infomlation
Note that if you enabled QUICK ARM for the partition (field *21), the [#l key
can be pressedinstead of entering the partition's security code,for any of the
arming procedures(Away, Stay, Instant, Maximum, etc.).The securitycodeis
alwaysrequired, however,when disarmin g the system.
The keypad allowsthe user to arm and disarm the system, and perform other
systemfimctions,suchas bypassingzones,and display zone descriptors.Zone
and system conditions(alarm, trouble, bypass) are displayed in the Display
Window.
When an alarm occurs,keypad sounding and external sounding will occur,
and the zone(s) in alarm will be displayed on the keypad. Pressing any key
vdl silence the keypad sounder for 10 seconds.Disarming the system will
silenceboth keypad and external sounders. When the system is disarmed,
any zones that were in an alarm condition during the armed period will be
displayed (memory of alarm). To clearthis display, simply repeat the disarm
sequence (enter the securitycodeand pressthe OFF key)
again.
The keypads also feature chime annunciation, and 3 panic key pairs, or
individual panic keys (depending on keypad type - see
Panic Keys
below),for
silent, audible, fire or personalemergencyalsrms. These keys can noti@ the
central station of an alarm condition,if that serviceis connected.
Arming Functions
The
following is a brief list of system commands. For detailed information
concerningsystemfanctions,refer to the User's Manual.
Disarme~
Not Ready ....Before arming, the system must be in the
READY condition(all zones must be intact). If
the "NOT READY' message appears, press the
READY [*] key to displayfaultedzones.
Arming Away ......................
Enter code+ AWAY [2].
~
S~Y . ....................... Enter code+ $TAY [31.
~
~t
.................. Enter code+ INSTANT [7].
~~-
............. Enter code+ MAXtMUM [4].
Disarming
........................... Enter code+ OFF [1].
Bypassing Zones ................ Enter code+ BYPASS [6]+ zone number(s).
Forced (Quick) Bypass .....
(lf enabled)
To automatically bypass all faulted
zones, use the "Quick
Bypass"
method:
Enter code+ BYPASS, then wait for all open
zones to be displayed. Arm when display
idiCateS %Y'PSSS" and %eady to arm".
Chime Mode ........................
Enter code+ CHIME [9].
To turn chimeoff, enter code+ CHIME again.
SUMMARY OF ARMING MODES
I
I
Features for E~h i%znimz Mode
I
Arming
Exit
Entry
Perimeter
Kterior
Mode
Delay
Delay
ihmed
Ammed
AWAY
Yes
Yes
Yes
Yes
STAY
Yes
Yes
Yes
No
INSTANT
Yes
No
Yes
No
Yes
No
Yes
Yes