Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908
5.9.5 Inspection of the SpectroProofer
This inspection checks each part and function of the SpectroProofer operates normally.
INSPECTION CONTEXT
Each inspection item can be executed separately; however, it is
C H E C K
P O I N T
recommended to execute them all in the order given in the table
below.
Table 5-4. Check Items
Category
Order
Item
1
Sensors check
MOUNTER
2
Fan check
ONLY TESTS
3
CR move
4
Calibration check
Paper holder
5
check
Tile position
6
check
MOUNTER +
ILS TESTS
Colorimetry CR
7
Inspection
Colorimetry PF
8
Inspection
Take-up Reel USB
9
host check
Note : The program for this inspection is the English version only. The above table uses the
names displayed on the program.
ADJUSTMENT
Content
Ref.
Check if Mount Sensor and
p. 431
Thermistor are operating normally.
Check if Cooling Fan is operating
p. 433
normally.
Check if Carriage is operating
p. 434
normally.
Check if calibration was successful
p. 436
at the start-up.
Check if Paper Pressing Plate is
p. 437
operating normally.
Check if the white calibration tile
is installed in the correct
p. 439
attachment location, or is
contaminated.
Check if the Color Measurement
p. 440
Device is operating normally in CR
direction.
Check if the Color Measurement
Device is operating normally in PF
p. 441
direction.
Check if Auto Take-up Reel Unit
p. 442
and Mounter are correctly
connected.
ROCEDURE TO START THE INSPECTION PROGRAM
P
1.
Start the Service Program.
2.
Select
ADJUSTMENTS (Individual).
3.
Select
Checking SpectroProofer.
4.
Click "RUN" to start the program. (The 24 or 44 inches version of the program is
applied automatically according to the model selection of the main menu.)
The OS supporting the inspection program are Windows 2000
C A U T I O N
and Windows XP only.
If the red screen (NG screen) appears while inspecting, press
[Alt] + [E] keys on the computer's keyboard to return to the
menu screen.
Confirm that STATUS is
inspection. If it does not become READY, an error is occurring
in the printer or the connection is faulty.
Save the Service Program on the desktop or directly under the
C drive. If the storage location is deep in the hierarchy, some
program tools may not work correctly.
Figure 5-88. Inspection Program Start Screen
Tests
Revision I
READY
on the start screen for each
430
Confidential