Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908
6.
Remove the AID Board.
7.
Disconnect the connector (CN2), and the FFC (CN1) on the AID Board.
After installing the AID Board Cover, check the status of the cable
connected to the CN2 on the AID Board, and if the black and white
cables can be seen, place the white one over the black one.
<Black and white cables are hidden>
No treatment required
- Top right -
AID Board
Figure 4-148. Removing the AID Board
DISASSEMBLY & ASSEMBLY
<Black & white cables can be seen>
Place the white over the black
CN1
CN2
Disassembly and Assembly Procedure
When installing the AID Board before design change, it can be
C H E C K
reassembled by reversing the disassembly procedure in
P O I N T
"Disassembling procedure for the previous type before
design change" (p294)
When installing the new-shaped AID Board to the old main
body, follow the procedure below.
1.
Remove the Spindle Cover R.
2.
Remove the two screws that secure the AID Board mounting
plate, and remove the AID Board mounting plate.
- Top right -
3.
Secure the new AID Board and AID Board mounting plate with
the two screws.
4.
Fold the FFC as shown below and connect the connector and
the FFC to the AID Board.
- Top right -
CN2
Revision I
.
(p215)
AID Board + AID Board mounting plate
Folded part of FFC
CN1
Confidential
295