Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908
4.4.5 Paper Feed Mechanism
4.4.5.1 Paper Thickness Sensor
1.
Remove the Control Panel.
(p203)
2.
Remove the IC Cover R and the IC Shaft Cover R.
3.
Remove the Maintenance Tank R.
4.
Remove the Right Cover.
(p209)
5.
Remove the IC Cover L and the IC Shaft Cover L.
6.
Remove the Maintenance Tank L.
NOTE: There is no Maintenance Tank (L) mounted for the Epson Stylus Pro
7700/7710/7700M/7710M/7900/7910/WT7900/WT7910/7890/7908.
7.
Remove the Left Cover.
(p209)
8.
Remove the Top Cover.
(p214)
9.
Remove the screw that secures the Paper Thickness Sensor Mounting Plate, and
remove the Paper Thickness Sensor Mounting Plate.
A) Silver, Phillips, Bind S-tite with S.W & P.W. M3x6: one piece
In the next step, make sure to confirm the destination of each
C A U T I O N
connector. When connecting them again, be sure to restore the
original routing.
10. Disconnect the connectors from the Paper Thickness Sensors.
11. Disengage the hooks that secure the Paper Thickness Sensors, and remove the
Paper Thickness Sensors.
Be sure to refer to Chapter 5 "Adjustment"
A D J U S T M E N T
R E Q U I R E D
specified adjustments after replacing or removing the Paper
Thickness Sensor.
<Adjustment Item>
1.
Paper Thickness Sensor Position Adjustment
DISASSEMBLY & ASSEMBLY
(p206)
(p208)
(p206)
(p208)
See Figure 4-82.
See Figure 4-83.
(see p351)
and perform
Disassembly and Assembly Procedure
- Upper right -
Paper Thickness Sensor Mounting Plate
A
Figure 4-82. Removing the Paper Thickness Sensor Mounting Plate
- Upper right -
Connector
Figure 4-83. Removing the Paper Thickness Sensor
Revision I
Connector
Paper Thickness Sensor
Hook
Confidential
250