4.4.5.2 PW Sensor
1.
Remove the Control Panel.
(p203)
2.
Remove the IC Cover R and the IC Shaft Cover R.
3.
Remove the Maintenance Tank R.
4.
Remove the Right Cover.
(p209)
5.
Unlock the Carriage Unit and move it to the center.
6.
Remove the three screws that secure the Arm Unit, and remove the Arm Unit.
A) Silver, Phillips, Bind P-tite with S.W & P.W. M3x10: three pieces
When installing the Arm Unit, be sure to secure the Arm Unit with
the screws while pressing it toward the platen.
7.
Remove the screw that secure the PW Sensor Cover, and remove the PW Sensor
Cover.
B) Silver, Phillips, Bind machine screw M2x6 (bit: No.1): one piece
DISASSEMBLY & ASSEMBLY
(p206)
(p208)
(p201)
Disassembly and Assembly Procedure
Arm Unit
Figure 4-84. Removing the Arm Unit
B
PW Sensor Cover
Figure 4-85. Removing the PW Sensor Cover
Revision I
A
251