DCx Cameras
3.4.2.6.9 Image Infos
Select the menu
View > Image infos
Capture errors
This group box provides detail information on errors that occurred during an image capture process:
Error
API no destination memory
API conversion failed
API image locked
DRV out of buffers
DRV device not ready
USB transfer failed
DEV timeout
ETH buffer overrun
ETH missed images
90
to display a dialog box containing information on the image capture.
80
Description
There is no destination memory for copying the finished image.
The current image could not be processed correctly.
The destination buffers are locked and could not be written to.
No free internal image memory is available to the driver. The image was
discarded.
The camera is no longer available. It is not possible to access images
that have already been transferred.
The image was not transferred over the USB bus.
The maximum allowable time for image capturing in the camera was
exceeded.
Not applicable to DCx Cameras
#