5.5.2.4 Digital Output (Flash) Circuit

Digital output specifications
Output current (short-time)
Output current (permanent)
Output voltage
Breakdown voltage
Collector power dissipation
The digital output is galvanically isolated using an optocoupler to protect the camera and the PC against surges.
Only DC voltages may be applied to the digital output.
The output of the optocoupler can be used as an open collector or open emitter output. This means that the output
signal can be connected to ground or to the supply voltage. The output signal is active if the collector-emitter switch
is closed (software setting: Flash high active, see also the
Digital output wiring
The following figures show examples of how the digital output is wired.
494
Max.
500
150
30
50
125
Camera properties: Input/output
Wiring of the digital output as an open collector output
Wiring of the digital output as an open emitter output
mA
mA
V
V
mW