Serial Interface - THORLABS DCU223x Operation Manual And Sdk

Cdd and cmos cameras
Hide thumbs Also See for DCU223x:
Table of Contents

Advertisement

5.5.2.5 RS-232 Serial Interface
Attention
The General Purpose IO are not potential-free and have no protective circuit. Faulty wiring (overvoltage,
undervoltage or inverting the wiring when used as serial interface) can result in a damage in the electronics.
During operation as serial interface only LVCMOS levels are allowed to the connector pins. To get a serial RS-232
compliant interface, an external level shifter (LVCMOS/RS-232) is required.
Applying RS-323 levels directly to the pins as well as mixing up the signals RxD and TxD can destroy the camera
electronics!
Serial interface specification
Minimum output voltage
Maximum input voltage
Supported Baud rates
Transmission mode
Data bits
Stop bits
Parity
Note
With the 8N1 mode, the maximum payload data rate achievable is 80% of the selected baud rate.
Serial interface wiring (UART)
The following figure shows the wiring of the serial interface with GPIO 1 as camera-side output (TxD) and GPIO 2
as camera-side input (RxD). The GPIO must be configured accordingly (see
© 2013 Thorlabs GmbH
Signal level "Low"
Signal level "High"
Signal level "Low"
Signal level "High"
Full duplex, 8N1
Serial interface connector (UART)
Min.
0
2.0
Min.
0
2.0
9.600
19.200
38.400
57.600
115.200
8
1