Diagram of Decision Process
Module last booted in
Yes
chassis becomes active
module
Figure 15-33. Active Module Decision Flow Chart at Boot
Notes on How the Active Module is Determined
Both management modules start to
Yes
Switch fails to boot
Module passing selftest
Yes
becomes active
One module booted
No
In chassis
No
Module 1 becomes
Yes
active module
Module 2 becomes
Yes
active module
Module active last time
Yes
becomes active module
Module standby last
Yes
time becomes active
module
Redundancy (Switch 8212zl)
boot
Both modules fail
selftest
No
One module fails
selftest
No
Both modules
were booted
In this chassis
Yes
Module 1
booted most recently
No
Module 2
booted most recently
No
Only one
module was active
on last boot
No
Only one
module was on
standby last
boot
No
Module in lowest slot
becomes active
15-45