Enabling And Configuring Snmp Inform; Operating Notes - HP ProCurve Management And Configuration Manual

Table of Contents

Advertisement

N o t e

Operating Notes

You must explicitly set snmp-server response-source if you wish to change
the default behavior. (rfc-1517)
This option is global and is applied to all interfaces that are sending SNMP
responses or SNMP trap pdus.
Only the source IP address field in the IP header for the SNMP response
pdu is altered.
Only the source IP address field in the IP header for the SNMP response
pdu is altered.
The source IP address field in the IP header and the SNMPv1 Agent
Address field for the SNMP trap pdu is altered.

Enabling and Configuring SNMP Inform

You can use the snmp-server host inform command (SNMPv2c only) to send
inform requests when certain events occur. When an SNMP Manager receives
an inform request, it can send an SNMP response back to the sending agent.
This lets the agent know that the inform request reached its destination.
If the sending agent does not receive an SNMP response back from the SNMP
Manager within the timeout period, the inform request may be resent, based
on the retry count value.
You must specify an IP address that will receive the notifications and the
community name.
Syntax:
[no] snmp-server host <ip-address> <community name> [<non | all | non-
info | critical | debug >] [[inform] [retries <count>] [timeout <interval>]]
Enables or disables the inform option for SNMP and allows
you to configure options for SNMP inform requests.
retries: Maximum number of times to resend an inform
request. Default: 3
timeout: Number of seconds to wait for an acknowledgement
before resending the inform request. Default: 15 seconds
The retries and timeout options are not used when using trap requests.
Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
14-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procurve 8200zl

Table of Contents