HP ProCurve Management And Configuration Manual page 159

Table of Contents

Advertisement

N o t e
Figure 7-3. Example of Executing the Console Command with Multiple Parameters
N o t e
If you change the Baud Rate or Flow Control settings for the switch, you
should make the corresponding changes in your console access device. Oth­
erwise, you may lose connectivity between the switch and your terminal
emulator due to differences between the terminal and switch settings for these
two parameters.
All console parameter changes except events require that you save the config­
uration with write memory and then execute boot before the new console
configuration will take effect.
For example, to use one command to configure the switch with the following:
VT100 operation
19,200 baud
No flow control
10-minute inactivity time
Critical log events
you would use the following command sequence:
The switch implements the Event Log change immediately. The switch implements
the other console changes after executing
When using redundant management, console settings, such as mode, flow-
control and baud-rate, are the same on both management modules. There
cannot be individual settings for each management module.
Interface Access and System Information
Interface Access: Console/Serial Link, Web, and Inbound Telnet
write memory
reload
and
.
7-7