HP ProCurve Management And Configuration Manual page 435

Table of Contents

Advertisement

ProCurve(config)# show redundancy
Settings
------- -
Mgmt Redundancy : Disabled
Statistics
--------- -
Failovers
Last Failover :
Slot Module Description
---- ---------------------------------------- -------- ----------- ---------
MM1
ProCurve J9092A Management Module 8200zl Active
MM2
ProCurve J9092A Management Module 8200zl Offline
FM1
ProCurve J9093A Fabric Module 8200zl
FM2
ProCurve J9093A Fabric Module 8200zl
ProCurve Switch 8200zl(config)# redundancy active-management standby
On the next system boot, the standby will become active.
ProCurve(config)# boot
The other management module is not in standby mode and this command will
not cause a switchover. System will reboot from primary image.
Do you want to continue [y/n]? y
(After system reboots...)
ProCurve(config)# show redundancy
Settings
------- -
Mgmt Redundancy : Disabled
Statistics
--------- -
Failovers
Last Failover :
Slot Module Description
---- ---------------------------------------- -------- ---------- ----------
MM1
ProCurve J9092A Management Module 8200zl Standby
MM2
ProCurve J9092A Management Module 8200zl Active
Figure 15-6. Example Showing Results of Switching to Standby Module when Redundancy is Disabled
disabled. An example of making the offline management module become the
standby management module when redundancy is disabled is shown in Figure
15-6.
: 0
: 0
Redundancy disabled
Status
Enabled
Enabled
Redundancy disabled
Status
Redundancy (Switch 8212zl)
Using Redundant Management
SW Version
Boot Image
K.12.30
Primary
K.12.30
Primary
SW Version Boot Image
K.12.30
Primary
K.12.30
Primary
15-11