Redundancy (Switch 8212zl)
Using Redundant Management
ProCurve(config)# redundancy active-management management-module2
On the next system boot, the management-module2 will become active.
ProCurve(config)# boot system
(boot occurs...)
ProCurve(config)# show redundancy
Settings
--------
Mgmt Redundancy : enabled
Statistics
----------
Failovers
Last Failover :
Slot Module Description
---- ---------------------------------------- ------
MM1
ProCurve J9092A Management Module 8200zl Standby K.12.30
MM2
ProCurve J9092A Management Module 8200zl Active
FM1
ProCurve J9093A Fabric Module 8200zl
FM2
ProCurve J9093A Fabric Module 8200zl
Figure 15-5. Setting a Management Module to be Active on the Next Boot
15-10
management-module2: Configures management-module 2 as
the active management module for the next system boot.
standby: Configures the current standby module as the active
management module for the next system boot if redundancy
is enabled. If redundancy is disabled, it will become enabled
as a standby module at the next boot or failover event.
If the specified management module is not there or is in failed mode, this
message displays:
The <specified module> is not present or is in failed
state.
Figure 15-5 shows an example of setting management module 2 to be the active
management module.
: 0
If redundancy has been disabled and you specify the standby module with the
active-management command, upon rebooting the offline module becomes the
standby module. The state of redundancy (enabled or disabled) is based on
the value in the configuration file in the offline (now standby) module. The
configuration files haven't been synchronized if redundancy has been
Status
SW Version
----------
K.12.30
Enabled
Enabled
Boot Image
----------
Primary
Primary