HP ProCurve Management And Configuration Manual page 376

Table of Contents

Advertisement

Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
ProCurve# show sflow 2 sampling-polling A1-A4
Port
| Sampling
| Enabled
----- + -------- -------- ------
A1
Yes(2)
A2
---
A3
No(1)
A4
Yes(3)
Figure 14-15. Example of Viewing sFlow Sampling and Polling Information
N o t e
14-32
Number denotes the sampling/polling instance to which the receiver is coupled.
Rate
Header
40
128
---
---
0
100
50
128
The sampling and polling instances (noted in parentheses) coupled to a
specific receiver instance are assigned dynamically, and so the instance
numbers may not always match. The key thing to note is whether sampling or
polling is enabled on a port, and the sampling rates or polling intervals for the
receiver instance configured on each port.
Dropped
|
Polling
Samples
|
----------
+
1234567890
0
Yes(1)
898703
0
Enabled
Interval
-------
--------
---
-- -
60
No
30
No(3)
0

Hide quick links: