Item
Coolant capacity
(L {US qt, Imp qt})
Cap valve opening pressure
Radiator
cap
(kPa {kgf/cm
Type
Initial-opening
temperature
Thermostat
Full-opening
temperature
Full-open lift
Type
Number
Cooling fan
Blade
Outer
diameter
End Of Sie
FUEL AND EMISSION CONTROL SYSTEMS
Item
Idle speed
Ignition timing
E/L ON
Idle-up speed
A/C ON
P/S ON
CO concentration
HC concentration
Fuel pressure
Hold pressure
2
(kPa {kgf/cm
, psi}
Fuel injector
Fuel leakage
Injection volume
(ml {cc, fl oz}/15 sec.)
Resistance
(ohm) [20°C {68°F}]
End Of Sie
TECHNICAL DATA
L8
2
, psi})
(°C
{°F})
(°C
{°F})
(mm {in})
Cooling fan No.1: 5,
Cooling fan No.2: 7
(mm
{in})
L8
650—750
(rpm)
(700±50)
(BTDC°/
Appro. 10/700
rpm)
650—750
(700±50)
refrigerant
pressure
switch
(middle)
700—800
OFF
(750±50)
refrigerant
pressure
switch
(middle) ON
700—800
(750±50)
More than 408
{4.2, 59}
(drop/2 minutes)
51—77 {51—77,
1.8—2.7}
11.4—12.6
Engine
LF
7.5 {7.9, 6.6}
113—142 {1.15—1.44, 16.4—20.6}
Wa, bottom-bypass
80—84 {176—183}
90{194}
8.0{0.32} min.
Electrical
(Ecept for
(For Israel)
Israel)
Cooling fan
Cooling fan
No.1:7
No.1:5
Cooling fan
Cooling fan
No.2: 5
No.2: 7
300 {11.8}
Engine
LF (ATX)
LF (MTX)
650—750
600—700
(700±50)
(650±50)
Appro. 10/700
Appro. 10/650
650—750
650—750
(700±50)
(700±50)
650—750
(700±50)
700—800
(750±50)
700—800
(750±50)
650—750
650—750
(700±50)
(700±50)
Within the regulation
More than 408
More than 408
{4.2, 59}
{4.2, 59}
Less than 1
64—84 {64—84,
64—84 {64—84,
2.3—3.0}
2.3—3.0}
11.4—12.6
11.4—12.6
A6E931001001W03
L3
Cooling fan No.1: 7,
Cooling fan No.2: 5
320 {12.6}
A6E931001001W04
L3
600—700
(650±50)
Appro. 10/650
650—750
(700±50)
TD
700—800
(750±50)
650—750
(700±50)
More than 408
{4.2, 59}
73—96 {73—96,
2.6—3.3}
11.4—12.6
TD–3

Advertisement