Mazda 6 2002 Workshop Manual page 1166

Hide thumbs Also See for 6 2002:
Table of Contents

Advertisement

STEP
9
INSPECT TO SEE WHETHER MALFUNCTION
IS IN REFRIGERANT PRESSURE SWITCH OR
REFRIGERANT AMOUNT
• Inspect refrigerant pressure switch.
• Is it okay?
10
INSPECT TO SEE WHETHER MALFUNCTION
(LACK OF CONTINUITY) IS IN A/C CONTROL
SIGNAL CIRCUIT (BETWEEN A/C RELAY
AND PCM) OR ELSEWHERE
• Does cool air blow out when terminal E of A/
C relay connector (A/C control signal) is
grounded?
11*
INSPECT TO SEE WHETHER MALFUNCTION
(LACK OF CONTINUITY) IS IN PCM OR
WIRING HARNESS (BETWEEN A/C RELAY
AND PCM)
• Test voltage at the A/C relay control signal
terminal of PCM.
• Is voltage approimately 12 V?
12*
INSPECT TO SEE WHETHER MALFUNCTION
IS IN MAGNETIC CLUTCH OR ELSEWHERE
• Test voltage at the following terminal of
magnetic clutch thermal protector.
— Terminal A (magnetic clutch operation
signal)
• Is voltage approimately 12 V?
13
INSPECT FUSE
• Are A/C relay power supply fuses okay?
14
INSPECT WIRING HARNESS BETWEEN
FUSE BLOCK AND A/C RELAY FOR LACK
OF CONTINUITY
• Test voltages at following terminals of A/C
relay.
— Terminal A (A/C relay control signal)
— Terminal C (A/C control signal)
• Are voltages approimately 12 V?
15
INSPECT TO SEE WHETHER MALFUNCTION
IS IN A/C RELAY OR WIRING HARNESS
(BETWEEN A/C RELAY AND MAGNETIC
CLUTCH) AND EVAPORATOR
TEMPERATURE SENSOR
• Test voltage at the following terminal of A/C
relay.
— Terminal D (magnetic clutch operation
signal)
• Is voltage approimately 12 V?
16
INSPECT EVAPORATOR TEMPERATURE
SENSOR
• Inspect evaporator temperature sensor.
• Is it okay?
17
CONFIRM THAT MALFUNCTION SYMPTOMS
DO NOT RECUR AFTER REPAIR
• Does cool air blow out? (Are the results of
refrigerant system performance test okay?)
End Of Sie
NO.9 NOISE WHILE OPERATING A/C SYSTEM
9
Noise while operating A/C system.
DESCRIPTION
• Noise from magnetic clutch, A/C compressor, hose or refrigerant line.
• Magnetic clutch operation noise (Step 4)
POSSIBLE
• A/C compressor vane noise (Steps 5—13)
CAUSE
• A/C compressor slippage noise (Steps 14—17)
• Hose or refrigerant line interference noise (Step 18)
U–76
TROUBLESHOOTING
INSPECTION
Yes If refrigerant amount is empty, replace condenser, vaccum
refrigerant line more than 30 minutes by vacuum pump,
and add refrigerant to specified level, then go to Step 17.
No
Replace refrigerant pressure switch, then go to Step 17.
Yes Release short, then go to net step.
No
Go to Step 12.
Yes Inspect PCM, then go to Step 17.
No
Repair wiring harness between A/C relay and PCM, then go
to Step 17.
Yes Inspect magnetic clutch, then go to Step 17.
No
Go to net step.
Yes Go to net step.
No
Replace fuse, then go to Step 17. If fuse burns out
immediately, go to net step.
Yes Go to net step.
No
Repair wiring harness between fuse block and A/C relay,
then go to Step 17.
Yes Inspect wiring harness between A/C relay and magnetic
clutch.
• If above wiring harness is OK, go to net step.
• If above wiring harness malfunctions, repair wiring
harness, then go to Step 17.
No
Replace A/C relay, then go to Step 17.
Yes Go to net step.
No
Replace evaporator temperature sensor, then go to net
step.
Yes Troubleshooting completed. Eplain repairs to customer.
No
Recheck malfunction symptoms, then repeat from Step 1 if
malfunction recurs.
ACTION
A6E858001038W11

Advertisement

Table of Contents
loading

This manual is also suitable for:

6

Table of Contents