Maintenance Actions; Figure 3-96: Maintenance Actions - AudioCodes Mediant 2000 User Manual

Media sip gateway
Hide thumbs Also See for Mediant 2000:
Table of Contents

Advertisement

3.5.1.3

Maintenance Actions

The 'Maintenance Actions' page allows you to perform the following operations:
Reset the device (refer to ''Resetting the Device'' on page 228)
Lock and unlock the device (refer to ''Locking and Unlocking the Device'' on page 229)
Save the configuration to the device's flash memory (refer to ''Saving Configuration'' on
page 230)
To access the 'Maintenance Actions' page, take this step:
On the Navigation bar, click the Management tab, and then in the Navigation tree,
select the Management Configuration menu, and then choose the Maintenance
Actions page item.
3.5.1.3.1 Resetting the Device
The 'Maintenance Actions' page allows you to remotely reset the device. In addition, before
resetting the device, you can choose the following options:
Save the device's current configuration to the device's flash memory (non-volatile).
Perform a graceful shutdown, i.e., device reset starts only after a user-defined time
expires (i.e., timeout) or after no more active traffic exists (the earliest thereof).
To reset the device, take these 6 steps:
Open the 'Maintenance Actions' page (refer to ''Maintenance Actions'' on page 228).
1.
Under the 'Reset Configuration' group, from the 'Burn To FLASH' drop-down list, select
2.
one of the following options:
'Yes': The device's current configuration is saved (burned) to the flash memory
prior to reset (default).
'No': Resets the device without saving the current configuration to flash (discards
all unsaved modifications).
SIP User's Manual
Figure 3-96: Maintenance Actions Page
228
Mediant 2000
Document #: LTRT-68808

Advertisement