BRIDGE MODE SETTING SCREEN
9. [Expansion] Menu (continued)

M Abnormal Condition Monitoring

Set the monitor function for the communication error.
• This is an example.
q LAN Port Downlink .........
Monitoring
Select "Enable" to automatically detect the communication error.
When the Ethernet cable disconnects from the VE-PG3's [LAN] port, the
[WAN] LED lights Orange, and the error message is displayed on the
"SYSLOG" screen in the "Information" menu.
Control Output
Select "Enable" to output the error detect signal from the B1/B2 terminal
(+/–).
• Select "Relay circuit" in the Control Circuit] item on the [EXT Output](1/2), or
[EXT I/O](1/2) screen.
While the error detect signal sends, the VE-PG3 cannot receive signals from
the external device that is connected to the B1/B2 terminal (+/–).
5-109
[Expansion]–[Abnormal Condition Monitoring]
(Default: Disable)
(Default: Disable)