Operating instructions DV 80.2 / DV 120.2 / DV 125.2 / DV 200.2 / DV 200.2 PW
17.3.1 View/modify parameters
Datei:BA_DV80.2_120.2_125.2_200.2_200.2PW_9625769_EN_2002-10.doc
MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
Indication
this display by pressing the "accept" key.
Now, the first parameter will be displayed with a value.
Press the "I" key to go forwards and the "III" key to go backwards, until the parameter you
require is displayed.
Confirm the parameter to be modified by pressing the "accept" key, the value will flash. +
Press the "I" key to increase the value, the "III" key to decrease the value, and the
"accept" to save the value.
You can leave this level by pressing the "0" key.
See 17.4 for list of parameters
17.3.2 Ventilating the rinse aid inlet
this display by pressing the "accept" key.
Now the dosage pump will be activated and the remaining running time will be indicated.
You can leave this level by pressing the "0" key. The ventilation will be interrupted off.
17.3.3 Ventilating the detergent inlet
this display by pressing the "accept" key.
Now the dosage pump will be activated and the remaining running time will be indicated.
You can leave this level by pressing the "0" key. The ventilation will be interrupted off.

W e reserv e the right to change execution and construction!