‡F LOSS RESET
Sets how long video loss conditions exist before alarm reset and return to normal operation.
Reset range is 1 sec. to 29 min. 59 sec.
‡G SENSOR RESET
Sets how long alarm conditions exist before sensor alarm reset and return to normal
operation.
If SENSOR INPUT ‡A to TRIG, reset range is 1 sec. to 29 min. 59 sec.
If SENSOR INPUT ‡A to LEVEL, setting here will be operationally invalid.

6-9-2. Regarding Alarm Display

Response examples for the three available alarm display settings are as shown below.
u
FULL
Full screen display of each alarm channel.
•ž Example:
CH1 and CH2 alarm occurrence times overlap. Display changes between channels every
1sec. during alarm overlap interval.
Normal
Operation
u
STAY
Display locks on last channel in alarm and continues to display last alarm channel even after
alarm conditions are reset.
Normal
Operation
u
SPLIT
Display goes to appropriate split screen to show all cameras in alarm at same time.
(Continued following page.)
Changes every sec.
CH1
full
CH
CH
screen
1
2
CH1
CH2
Alarm
Alarm
input
input
CH1
full
CH2
screen
screen
CH1
CH2
Alarm
Alarm
input
input
CH
CH
CH2 full
1
2
screen
CH1
Alarm
reset
full
(until operator cleared)
CH1
Alarm
reset
78
Normal
Operation
CH2 Alarm reset
CH2 Alarm reset