6-3-2. Pre Alarm Record

When you input PRE ALARM as the REC MODE setting in the RECORD menu, settings
displayed in the menu should be as indicated below. See sec. '5-1. Accessing MAIN Menu'
for information on making menu selections.
‡@
‡A
‡B
‡C
‡D
‡E
‡F
‡G
‡H
‡I
‡J
Where:
‡H TOTAL ALARM REC
Sets total time camera record is performed before and after alarm signal input. Setting range
is up to 19 min. 59 sec. (Note that min. total time varies depending on number of channels
being recorded.)
‡I
PRE ALARM REC
Sets time camera record is performed before alarm signal input. (Time recording occurs after
alarm input will be auto calculated based on 'total' time setting at ‡H minus 'pre' setting here.
For example, if total is to 8 min., and 3 min. set here, record will be performed for 5 min. after
alarm input occurs.)
(Continued following page.)
PROGRAM – NO.1
REC MODE – PRE ALARM
QUALITY – NORMAL
AUDIO – OFF
REC CHANNEL
NORM = 16 FAST = 0 SENS = 0
TIMELAPSE MODE
UPDATE (NORM, SENS) = 1.60SEC
UPDATE (FAST) =***.**SEC
TOTAL REC TIME= 30H52M
TOTAL ALARM REC – 1M 0S
PRE ALARM REC – 0M 30S
TRIGGER
SET
Settings ‡@ - ‡B are not explained here as they are the same
for all recording modes. See sec. '6-3. Record Programming'
previous.
Settings ‡C - ‡G are not explained here as they are the same
as for CONTINUOUS REC MODE. See sec '6-3-1.
Continuous Record' previous.
Setting UPDATE MODE at ‡F may make simultaneous
record / playback impossible depending on number of
camera channels being recorded.
See sec. '6-3-4. Regarding Record Channel Setting' and '6-
3-5. Regarding Timelapse / Update Mode Setting' following
regarding unit operation.
Settings made cannot exceed 'total' time setting at ‡H .
[RECORD]
0.10SEC
EXIT