SWITCHOVER
If this setting made, and multiple channel alarms occur, all cameras concurrently in alarm will
be switched every field and recorded during the multiple alarm period.
Record
CH1 - 16
u
ALL CHANNELS
All channels (alarm and normal) sequenced each frame, except SKIP set channels, and
recorded real time during alarm. Exception: If alarm occurs at SKIP set channel, that
channel will also be recorded.
u
PRIORITY
Same response as ALL CHANNEL setting (D above), except alarm channels go to FAST
update mode, other channels go to NORM update mode.
u
SEQUENCE
If you are using sensor devices to input alarms, and they are area mounted (not on each
camera), this setting allows you to set which cameras in the sensor covered area are
recorded and for how long. Settings for cameras and record time are made in ALARM SEQ
REC sub menu shown below.
(Continued following page.)
Alarm video (realtime)
CH1
only
record
CH1
Alarm
input
PRIORITY alarm record cannot be performed if the
number of alarm channels is more than the number of
non-alarm channels, or if more than 7 channels are in
alarm at the same time.
If PRIORITY alarm record cannot be performed, setting
will automatically change to ALL CHANNEL. Setting will
not automatically return to PRIORITY after alarm reset.
TRIGGER sub menu is invalid when ALARM REC MODE
is set to SEQUENCE.
CH1 and 2
CH2
alternate
record
record
CH2
CH1
Alarm
Alarm
input
reset
Important
Note
64
Record
only
CH1 - 16
CH2 Alarm reset