Ganz CDR-16T Operation Manual page 71

Table of Contents

Advertisement

ALARM1
ALARM2
ALARM3
ALARM4
In ALARM SEQ REC sub menu, ALARM1 – 4 correspond to alarm inputs from devices that
are not mounted to your observation cameras. Response for up to 4 camera veiwed areas
can be programmed per each alarm reference. Record time for each camera related to an
ALARM can be independently set.
It also, sets cameras used and alarm record time needed at each one. Any specified camera
can be set to alarm record for 1 – 30 seconds upon input from the related ALARM device.
For example, assume an input from ALARM 2 (sensor device 2) is received by CDR-16T. If
the settings shown in the menu example on the previous page are made, response will be as
shown below.
‡@ Sensor device 2 inputs alarm.
‡A CH5 camera recorded for five seconds (real time).
‡B CH6 camera recorded for five seconds (real time).
‡C CH7 camera recorded for 10 seconds (real time).
‡D CH8 camera recorded for 30 seconds (real time).
‡E Record returns to normal operation (continuous record setting).
Alarm video (realtime)
Record
‡A CH5
5 sec.
CH1 - 16
‡@ Alarm 2
input
‡A
‡@
[ALARM SEQUENCE REC]
CH
TIME
1.CH1
•| 5S
3.CH3
•| 10S
1.CH5
•| 5S
3.CH7
•| 10S
1.CH9
•| 5S
3.CH11 •| 10S
1.CH13 •| 5S
3.CH15 •| 10S
SET
‡B CH6
‡C CH7
5 sec.
10 sec.
‡B
‡C
65
CH
TIME
2.CH2
•| 5S
4.CH4
•| 30S
2.CH6
•| 5S
4.CH8
•| 30S
2.CH10 •| 5S
4.CH12 •| 30S
2.CH14 •| 5S
4.CH16 •| 30S
EXIT
‡D CH8
30 sec.
Record
CH1 - 16
‡D

Advertisement