6-3-3. One Shot Record

When you input ONE SHOT as the REC MODE setting in the RECORD menu, settings
displayed in the menu should be as indicated below. See sec. '5-1. Accessing MAIN Menu'
for information on making menu selections.
‡@
‡A
‡B
‡C
‡D
‡E
Where:
‡C INTERVAL
Sets fixed time interval between 'take' of each video capture shot. Selectable 1 – 240 fields.
For example, if you set 50 FIELDS, one frame of video from alarm channel will be captured
every 50 fields.
‡D TAKES
Sets how many video capture 'takes' are performed during an alarm. Selectable as 1 – 20
max. For example, if you set 5 TAKES, five 1 – frame shots will be captured and alarm
recording will end.
(Continued following page.)
PROGRAM – NO.1
REC MODE – ONE SHOT
QUALITY – NORMAL
INTERVAL – 5FIELDS
TAKES – 5TAKES
TRIGGER
Settings ‡@ – ‡B are not explained here as they are the
same For all recording modes. See sec. '6-3. Record
Programming' previous.